16.0 LA70 and LA70M Range Limiter
TM70 radio remote control systems LA70 Infrared Range Limiter (LA70 IR Limiter) option
prohibits the system from being operated outside a defined working area. The operator must be
within Line-Of-Sight of the LA70 IR module to control the machine.
The system consists of one or more LA70 Infrared Modules. The LA70 IR module is installed in
a fixed position or on the controlled crane and positioned to cover the targeted working zone as
shown in Figure 22. Range Limited TM70 RF transmitters contain an infrared sensor that
receives the information from the LA70 IR module, analyzes the information, and then acts as a
permissive. If the transmitter does not receive the infrared data within a pre-determined time
(factory setting is four (4) seconds), the outputs are deactivated.
Figure 22 shows some LA70 IR Range Limiter application examples.
Figure 22: Range Limiter Application Examples